1 This thermostat has been discontinued. Replaced by TH8000 series.
Provide electronic control of 24 Vac single-stage or multistage heating and cooling systems, including heat pump systems.
Part Number
Application
Program
Change- over
Power Method
Stages
Switch Positions
System
Fan
Terminal Designations
Finish
T8600D2028
Gas, oil or electric 24 Vac Systems
7 day
Auto/ manual selectable
Power stealing
1 heat 1 cool
HEAT, OFF, COOL, AUTO
ON- AUTO
Y,W,G,R,RC,OT, OT,O,B
Taupe
T8600D2069
Y,W,G,R,RC,OT, OT,O,B
Premier White
T8601D2019
Hard- wired
Y,W,G,R,C, OT,OT,O,B
Premier White
T8602D2000
24 volt, 750 millivolt gas heating only systems, or 750 millivolt gas heating systems with 24 volt cooling systems.
Battery Powered
Y,W,G,R,Rc, O,B,OT,OT
Taupe
T8602D2018
Y,W,G,R,Rc, O,B,OT,OT
Premier White
T8611G2002
Heat Pump
Hard- wired
2 heat 1 cool
EM HT, HEAT, OFF, COOL, AUTO
Y1,W1,W2,G,E,L, R,C,O/B,OT,OT, X1,X2
Taupe
T8611G2028
Y1,W1,W2,G,E,L, R,C,O/B,OT,OT, X1,X2
Premier White
T8611M2025 with L terminal output (defrost reset)
3 heat 2 cool or 2 heat 1 cool
R,C,Y1,Y2,W3,E, O/B,G,L,X1,X2, OT,OT
Premier White
T8624D2004
Multi-Stage Heat-Cool
up to 2 heat 2 cool
HEAT- OFF- COOL- AUTO
Y1,Y2,W1,W2,G, R,Rc,C,O,B,OT,OT
Taupe
T8624D2012
Premier White
Notes concerning the "powerstealing" thermostats
Let me suggest
that if you have or can run a common wire to the thermostat, it may save you a headache or two.
I recommend the "hardwired" T8601Dxxxx rather than the "powerstealing" T8600Dxxxx. The T8601Dxxxx has never shown
any incompatibility with certain other modern electronically controlled components in the
systems as is occasionally the case with the "powerstealing" model (the T8600Dxxxx).
It is rather rare, but it does happen. I have had some complaints about the
display sporadically going blank. It turned out to be problems in the heating systems and
a limit safety was tripping and killing the power to all the system (thermostat included).
But these are annoyances to the owner and occupants as they are not aware of the
cause and I get calls wanting refunds. Therefore, I usually explain this to potential purchasers
of the "powerstealing" models.
See even more about the T8600 Series Thermostats and a more detailed PICTURE.
Check out the TROUBLESHOOTING GUIDE.
Click here and send me your request by e-mail.