Honeywell® Logo

Honeywell® products
at discounted prices

  HEPA portable filters
HEPA Portable
Powered filter
Chronotherm III Thermostat
Honeywell®
Chronotherm III
Thermostats
Wireless & regular programmable thermostats
Honeywell®
Chronotherm IV
Thermostats
Honeywell® or Skuttle Humidifiers
Honeywell® &
Skuttle® Humidifiers
Reznor Unit Heaters UDAP
Reznor®
Unit Heaters
  
colored bar gif


Educate Me Section

Educate Me/Home
James A/C Co./Home

Diagnosis of problems
Understanding refrigeration
Homeowner helpful hints
Filtration & More
Understanding thermostats
Outside units and safety
Indoor Coils and drains
Links & Search


Air Purification Products

Pleated filters 40% 1 in.
Pleated filters 40% 2 in.
Pleated filters 60% 2 in.
Pleated filters 40% 4 inch
Pleated filters 60% 4 inch
Media filters 4 3/8 inch
Frame & filters 4 3/8 inch
Generic Media
Ultraviolet Lights
Electronic Air Cleaners
EAC Replacement Cells
Prefilters & Postfilters
Airwatch®, Monitors
Ventilation Units
Dampers & Actuators
CO & CO2 Sensors
Smoke Sensors
Portable HEPA Filter
Whole house HEPA Filter
Commercial HEPA Filter


Honeywell® Thermostats

COMPARE --
Programmable.pdf
Non-Programmable.pdf
Non-Digital.pdf

VisionPro™ IAQ *Best
VisionPRO© 8000  *Best
CommercialPRO™8220  *Best
CommercialPRO™7220  *Great
FocusPRO™ 6000  *Great
FocusPRO™ 5000  *Better
PRO™ 4000 *Better
PRO™ 3000 *Good
PRO™ 2000 *Basic
Low Voltage Accustat®
Programmable Line Voltage
Line Voltage Accustat®
Digital Round
Non-Digital bi-metal
Electronic Programmable
Heat Pump
Flush Mount
Non-Programmable
Sale Models
PC8900 Perfect Climate
Outdoor Sensors A or B
Telephone Access
Remote Room Sensors
Communicating Tstat
Telephone Access Module
Wireless Tstat
Networked Zoning
Honeywell® MiniZone®
Flood Alert Switch
Zoning Catalog.pdf
Chronotherm III Owner's Manual



Humidifiers

Bypass Disk
Bypass Flow Through
Power Flow Through
Steam Power
Controls & Components
Skuttle® Parts
Honeywell® Parts


Unit Heaters

Reznor® Garage Heating
Separated Combustion
Standing Pilot
Oil Fired
Hydronic
Indoor Heaters
UpFlow Indoor
Outdoor Heaters
Infrared Heaters
Tubular Radiant Heaters
Reznor Parts
Empire® Gas Heaters
What about old heater parts?
What size heater?


HVACR TOOLS

NRP® Manifold Sets
Gauges
Hoses
Heavy Duty Hoses
Miscellaneous


Miscellaneous

Transformers


Email Us
click here and send us an email

James A/C Co.

serving Do-It-Yourselfers since 1990.
Satisfying every customer....one at a time!


EDUCATE ME

Click to verify BBB accreditation and to see a BBB report.
spacer gif
Honeywell Themostats, Filters, and Electronic Air Cleaners
Call toll free 1-866-584-0355 or 1-903-759-2160
309 Patriot Circle, Longview, TX 75604-2240 colored bar gif

Diagnostic Chain


THINGS TO CHECK IF THE BURNERS ARE ON AND OFF WHILE FAN STILL RUNS:

MOST LIKELY CAUSES:

  • System airflow has to be a specific amount or the limit switch will shut off the gas when the chamber gets too hot. Check the FILTER, RETURN AIR, EVAPORATOR COILS and DUCTS for problems. It is not likely the limit switch is faulty.
  • Fan and limit switch combination controls are on some units and if the fan part of it is not turning on the fan properly, then the limit switch will cycle the heat off and on. Watch for this and re-adjust the temperature setting or replace the control as needed.
  • Heat anticipator set too low on the thermostat. Move the graduation to a much larger number and later lower it in small increments until it is okay. See also Page Two of Thermostats for details of adjusting the heat anticipator.
LESS LIKELY CAUSES:

  • Loose wire connection to the automatic gas valve or safety switches can cause sporadic on and off of the main burners, too.
  • Excessive gas pressure may be overheating the chamber and it will cycle on the limit control. Call a service technician.



¹ Logos and pictures Copyright © 1999 Honeywell Inc. All rights reserved

Click here
click to send email for order
and send me your request by e–mail or phone.
1–866–584–0355 (toll free) or 903–759–2160 FAX 903–759–4605
color bar gif

If you have comments or suggestions, please email me at James' A/C Co.
Visa, MasterCard, Discover & American Express

Back
back to index page

longnet web design

spacer gif

honeywell® visionpro™ iaq thermostat
Honeywell®
VisionPro® IAQ

whole house control

Honeywell® FocusPro™ Thermostat
Honeywell® FocusPro

non-programmable

Honeywell® VisionPRO™ Thermostat
Honeywell® VisionPro

Replacement for obsolete Chronotherm III/IV

electronic air cleaner
Honeywell®
Electronic Air Cleaner

honeywell® media filters
Honeywell®
Media Filters

UV Lites & Bulb Replacements
Honeywell®
UV Lights & Bulbs

Honeywell® Carbon Monoxide Alarms
Honeywell®
Carbon Monoxide
Alarms

Honeywell® Electronic Air Cleaner Replacement Cells
Honeywell®
Electronic Air Cleaner

Replacement Cells

Honeywell® VisionPro™ Thermostat
Honeywell®
LineVoltPRO™

programmable

Honeywell's ZD12x8 Zone Damper
Honeywell
Rectangular Zone Dampers

Honeywell's ARD6 Single Blade Zone Damper
Honeywell
Round Zone Dampers

Reznor Infrared Suspended Gas Heater
Reznor
Infrared Heaters