Honeywell® Logo

Honeywell® products
at discounted prices

  HEPA portable filters
HEPA Portable
Powered filter
Chronotherm III Thermostat
Honeywell®
Chronotherm III
Thermostats
Wireless & regular programmable thermostats
Honeywell®
Chronotherm IV
Thermostats
Honeywell® or Skuttle Humidifiers
Honeywell® &
Skuttle® Humidifiers
Reznor Unit Heaters UDAP
Reznor®
Unit Heaters
  
colored bar gif


Educate Me Section

Educate Me/Home
James A/C Co./Home

Diagnosis of problems
Understanding refrigeration
Homeowner helpful hints
Filtration & More
Understanding thermostats
Outside units and safety
Indoor Coils and drains
Links & Search


Air Purification Products

Pleated filters 40% 1 in.
Pleated filters 40% 2 in.
Pleated filters 60% 2 in.
Pleated filters 40% 4 inch
Pleated filters 60% 4 inch
Media filters 4 3/8 inch
Frame & filters 4 3/8 inch
Generic Media
Ultraviolet Lights
Electronic Air Cleaners
EAC Replacement Cells
Prefilters & Postfilters
Airwatch®, Monitors
Ventilation Units
Dampers & Actuators
CO & CO2 Sensors
Smoke Sensors
Portable HEPA Filter
Whole house HEPA Filter
Commercial HEPA Filter


Honeywell® Thermostats

COMPARE --
Programmable.pdf
Non-Programmable.pdf
Non-Digital.pdf

VisionPro™ IAQ *Best
VisionPRO© 8000  *Best
CommercialPRO™8220  *Best
CommercialPRO™7220  *Great
FocusPRO™ 6000  *Great
FocusPRO™ 5000  *Better
PRO™ 4000 *Better
PRO™ 3000 *Good
PRO™ 2000 *Basic
Low Voltage Accustat®
Programmable Line Voltage
Line Voltage Accustat®
Digital Round
Non-Digital bi-metal
Electronic Programmable
Heat Pump
Flush Mount
Non-Programmable
Sale Models
PC8900 Perfect Climate
Outdoor Sensors A or B
Telephone Access
Remote Room Sensors
Communicating Tstat
Telephone Access Module
Wireless Tstat
Internet Conectivity
Networked Zoning
Honeywell® MiniZone®
Flood Alert Switch
Zoning Catalog.pdf
Chronotherm III Owner's Manual



Humidifiers

Bypass Disk
Bypass Flow Through
Power Flow Through
Steam Power
Controls & Components
Skuttle® Parts
Honeywell® Parts


Unit Heaters

Reznor® Garage Heating
Separated Combustion
Used-Oil-Fired
Infrared Heaters
Reznor Parts
Empire® Gas Heaters
What about old heater parts?
What size heater?


HVACR TOOLS

NRP® Manifold Sets
Gauges
Hoses
Heavy Duty Hoses
Miscellaneous


Accessories

Transformers
Contactors
Miscellaneous
Heating Parts
Bell & Gossett Pumps


Email Us
click here and send us an email

James A/C Co.

serving Do-It-Yourselfers since 1990.
Satisfying every customer....one at a time!

Click to verify BBB accreditation and to see a BBB report.

spacer gif
Honeywell Themostats, Filters, and Electronic Air Cleaners
Call toll free 1-866-584-0355 or 1-903-759-2160 fax 903-759-4605
309 Patriot Circle, Longview, TX 75604-2240 colored bar gif

THINGS TO CHECK IF THE COMPRESSOR WILL NOT START BUT THE FAN RUNS:

MOST LIKELY CAUSES:

  • High voltage wiring. Turn off the power to the unit and check all electrical wiring to the compressor. Check particularly for burned wires at the CONTACTOR, the RUN CAPACITOR, and inside the COMPRESSOR TERMINAL BOX on the side of the compressor. Check to see if the actual CONTACTS of the contactor are not damaged to the point they do not work. Make sure no insects have been trapped under the contacts and thus impeding the flow of current.
    picture of contactor Examine the contactor for unwanted object under the contacts or improper "making" (closing) of the contacts. The compressor may be getting voltage, but not the proper current.
  • Run capacitor. Examine the run capacitor or capacitors for "bulging" or for burned terminals or burned wires. If you suspect a problem with the capacitor, take it to an air conditioning contractor or supply house of air conditioning parts and ask them to check the INTERNAL capacitance of it.
  • Stuck Compressor. You may have to replace the compressor or the condensing unit because of this problem, but there are some attempts at repair to be made. By this, we mean that the motor or the pump inside the compressor is bound and will not turn even with the correct amount of voltage and current supplied to it. There are several ways to possibly remedy this and some are a more permanent repair than others, but most are only temporary fixes if the cause is binding of parts internally or bad INTERNAL BEARINGS. Don't laugh at the solutions I give. They will possibly gain you a few days of warm heat pump air or cool air conditioning:

    • Start assist component. Add a capacitor, bleed resistor and start relay to the compressor if none are already on it. If these already are in place and it is working but will not start the compressor, then you might try changing the capacitance of it to a larger size. wiring of start kit Notice the relay. Terminals 2 and 1 have a set of contacts that are closed until the coil of terminals 2 and 5 is energized and activated. This set of contacts will remain closed until voltage is applied to the coil of the relay AND the compressor gains enough speed. This is a second or less. While the contacts are closed and the voltage is applied, the capacitor is supplying another type of voltage to the compressor windings. This gives the compressor extra ability to start and run and it does so more quickly.

      Examine the start capacitor, if the unit has one, and look for a blown port or burned wires or loss of particles or fluid from it. You will need a capacitance checker to know if it is good otherwise and may need to take it to a service shop for testing. Take the relay as well. You can purchase a complete replacement kit for less than forty dollars if this is the solution.

      If you really want to know the working theory of these components, see start kits section.

    • Thermistor controlled "boosters".
      wiring of booster to run capacitor You might get by with one of the new thermistor controlled "boosters" if the compressor has no start assistance at present. Just push on the terminals for the booster onto the compressor's capacitor terminals as shown. They are good for "soft starts", but once energized will take several minutes to cool before they will work again.
    • Overheated compressor. Don't mistake an overheated compressor for one that is stuck. If a compressor is overly hot it will trip an internal protector and when it cools down it will re-set itself. If you turn off the electricity to the unit, you can cool it until it re-sets with a fairly small amount of water from a hose. Be careful not to create an electrical hazard with the water. Standing in water will increase your chances of a fatal electrical shock many times over.
    • Jolting it loose. If you could pick up the compressor and jostle it rudely, you might could get some of the internal parts of it to move just a bit and thus get off that impeded position it might be in, but this is unlikely that you can do this. The next best thing is a "shock treatment". Use a large sledge hammer and literally bang it briskly from a horizontal blow close to the top of the compressor. If this causes it to start working, it will fail again, but maybe not until you can get it replaced.

LESS LIKELY CAUSES:

  • Compressor oil. This is a less likely cause maybe, but maybe not. When a unit freezes up the oil will be washed out of the compressor and rest in the tubing and cooling coil.

    • One solution to this problem is to pack the compressor in ice for several hours and hope the migration of oil back to the compressor will be sufficient to lubricate it until it can recover enough the proper way while it runs normally. If you do this, you will need to leave the unit off, but with the power supply on for eight hours minimum after the ice is removed. This will let the compressor warming get the refrigerant back out of the compressor while allowing the oil to remain. This is a long-shot, but it may work if you have the time.

    • You could temporarily PUMP SOME OIL into the compressor, but this is probably beyond your scope and will require a service technician. If you do get the compressor running, you can recover the stranded oil more quickly if you shut the DISCHARGE VALVE considerably, but not closed, for a period of minutes and it will cause the system to run "starved" and will draw the oil back with the aid of the very low SUCTION PRESSURE and the very high pressure in the condenser coils.
spacer gif

honeywell® visionpro™ iaq thermostat
Honeywell®
VisionPro® IAQ

whole house control

Honeywell® FocusPro™ Thermostat
Honeywell® FocusPro

non-programmable

Honeywell® VisionPRO™ Thermostat
in2 Energy ICM®

Connects Thermostat to Computer and Internet.

electronic air cleaner
Honeywell®
Electronic Air Cleaner

honeywell® media filters
Honeywell®
Media Filters

UV Lites & Bulb Replacements
Honeywell®
UV Lights & Bulbs

Honeywell® Carbon Monoxide Alarms
Honeywell®
Carbon Monoxide
Alarms

Honeywell® Electronic Air Cleaner Replacement Cells
Honeywell®
Electronic Air Cleaner

Replacement Cells

Honeywell® VisionPro™ Thermostat
Honeywell®
LineVoltPRO™

programmable

Honeywell's ZD12x8 Zone Damper
Honeywell
Rectangular Zone Dampers

Honeywell's ARD6 Single Blade Zone Damper
Honeywell
Round Zone Dampers

Reznor Infrared Suspended Gas Heater
Reznor
Infrared Heaters

colored bar gif
If you have comments, suggestions or you solved a problem with the aid of this free site,
please email me at James' A/C Co.
Back To Cooling
Back To Heating
Back to Front Page

Longnet Web Design
Visa, MasterCard, Discover & American Express