Field® power venter³
Field Controls
®
Oil & Gas Heater
Parts
Chronotherm III Thermostat³
Honeywell®
Chronotherm III

Thermostats
Wireless & regular programmable thermostats³
Honeywell®
Chronotherm IV

Thermostats
Honeywell® or Skuttle Humidifiers³
Honeywell® &
Skuttle
® Humidifiers
BIG SALE
Reznor Unit Heaters UDAP³
Reznor®
Unit Heaters
maxitrol gas regulator poppet type³
Maxitrol
®
Gas Regulators & Parts
   
James' A/C Co.--Air Conditioning Center Home--James A/C Co. Pleated filters 40 percent 1 inch pleated filters 40 percent 2 inch pleated filters 40 percent 4 inch media filters 4 3/8 inch frame and filters 4 3/8 inch generic media filters ultraviolet lights electronic air cleaners eac replacement cells prefilters and post filters airwatch and monitors ventilation units damers and actuators co and co2 sensors smoke sensors compare programmable thermostats compare non-programmable thermostats Compare non-digital thermostats vision pro iaq the very best vision pro 8000 series best buy commercial pro 8220 best buy commercial pro 7220 great buy focus pro 6000 great buy focus pro 5000 good buy pro 4000 buy pro 3000 buy pro 2000 basic value low voltage accustat programmable line voltage line voltage accustat digital round non digital bi metal Electronic Programmable selections non programmable and sale model selections obsolete pc8900 perfect climate information PC8900, Chronotherm III/IV Outdoor Sensors Remote Room Sensors prior model communicating thermostats telephone access module wireless thermostat internet conectivity networked zoning mini zone controller thermostat guards zoning catalog pdf file chronotherm III owners manual humidifiers selection bypass flow through humidifier controls and components skuttle humidifier parts honeywell humidifier parts reznor garage type heaters heaters with separated combustion infrared heaters Reznor Parts and Prices Page parts availability information heater sizing information Field Controls oil and gas Miscellaneous and accessories transformers page contactors link honeywell heating parts link Bell & Gossett Pumps & parts maxitrol gas regulator page email to james a c co Click to verify BBB accreditation and to see a BBB report. Use without permission is prohibited. The BBB Accredited Business seal is a trademark of the Council of Better Business Bureaus, Inc. spacer gif
colored bar gif
Honeywell Thermostats, Filters, and Electronic Air Cleaners
Call toll free 1-866-584-0355 or 1-903-759-2160 or fax 903 759 4605
309 Patriot Circle, Longview, TX 75604-2240 colored bar gif
THINGS TO CHECK IF THE HEAD PRESSURE IS TOO LOW:

MOST LIKELY CAUSES:

  • Refrigerant undercharge is probably the most common cause of low head pressure. Refrigerant does not get used up. If the system is checked by subcooling and superheat measurements and indeed found to be low on refrigerant, then there is a LEAK IN THE SYSTEM. Someone has left it with a low charge, or someone or something has let it out. (Don't forget that some people "sniff" anything to get a feeling or bodily reaction. This does occur, too.)

    Household refrigerant is usually refrigerant-22. It is not likely to be dangerous unless inhaled in large quantity. It has the characteristics that allow it to displace oxygen in the air and thus in the body. It is not flammable. In fact, since it displaces oxygen, it retards fire. If breathed in pure state, it will make the voice very low and will give you a faint feeling and later a headache. Enough of it will suffocate you.
    If a refrigerant is in the presence of an open flame or an extremely hot surface, it will turn into a potent acid. The fumes from this acid are very harmful to humans and will cause violent involuntary defensive reactions by a person coming in contact with the vapor.

    Several clues may guide you to finding the leak. Look for oily spots at joints and fittings. About 15% of the systems oil will circulate with the refrigerant. If it leaks, then likely there will be some oil residue at the area of the leak. Check especially the service valves and caps and flare or compression fittings. If you suspect a spot, poor or spray some soapy solution on it to see if it bubbles. Don't necessarily expect large bubbles or a lot of them. Sometimes the leak will only produce a tiny white pin-point size spot. Of course, the technicians will use a very fine and expensive leak detection meter.

    Some leaks are difficult to repair and others are a waste of effort. If the leak is in the body of the evaporator coil, for example, you might as well just buy a new coil and be done with it. If it is in the end-loops of the coils, you may repair it today and the heat around the perimeter of the brazing may later cause several additional leaks to develop. If, however, you are ambitious and willing, then you can braze every joint that is "soldered" and you run a pretty good chance of having a permanent repair. Even this will only give you about a 50% chance, in my opinion, of it being a long lasting and profitable effort. But, if you are good at it and want to try, then go for it.

  • Cool ambient conditions will surely cause the pressures to be low. It is nearly impossible to check the refrigerant system in cool weather. Try to fix it when the outdoor temperature is above 70 degrees F. and the indoor temperature is never below 70 degrees F. If you add refrigerant to a system in too cool conditions, you will invariably overcharge the system.
  • Water on the condenser coils will also result in abnormally low pressures. Let it dry out and avoid even putting your hoses on the equipment in the rain. Even if you don't get moisture in the system, the rain will increase the chances that you might electrocute yourself. Please read the safety precautions from the home page. Always be cautious.
  • LESS LIKELY CAUSES:

  • Inefficient compressor valves, particularly the discharge valves, inside the compressor will produce a reduced head pressure. There is nothing you can do but change the compressor or the condensing unit.
  • TXV stuck open (see explanation in orifice-flow control device in Refrigerants and Charging) will cause an unusually high flow of refrigerant into the low side of the system and will of course reduce the head pressure in the process. Look for excessively high suction pressure and a cooling coil that is not cooling well and a compressor that is being flooded with cold liquid refrigerant. It will be likely be sweating all over and making strange sounds and begging to die. The superheat will be non-existent or excessively low. You may as well replace the TXV (thermostatic Expansion Valve), but you may also take it apart and lightly clean all the moving parts. Don't forget the "push-pins".
  • Iced evaporator will also contribute somewhat to lowering the head pressure. Look for sweating compressor, low or non-existent superheat and lack of adequate airflow from the supply grills from the indoor system. It may, however, seem to have good airflow while not being iced completely. You will likely have to visually examine the evaporator coils.
  • Leaking check-valve (on the heat pumps) will also cause the condition. You can feel the leakage by checking the temperature of the lines as the refrigerant goes through. No repair is likely possible. Change the valve.
    picture of system layout
  • Notice that this drawing of this system has two check valves. One is in the evaporator section and the other is in the condensing unit. The one we are checking now is the one in the evaporator section. Notice the direction-of-flow arrow. In the cooling mode, it is not supposed to let the liquid refrigerant by-pass the expansion valve (TXV) or the capillary tube if you have one or more of them. The check-valve in the condensing unit will be feeding refrigerant through in the correct position during the cooling cycle, so it is supposed to by-pass the flow control device in the condenser during cooling.
back to refrigerant page cooling

¹ Brand names, product names or trademarks listed belong to their respective holdings.


Click here
click to send email for order
and send me your request by e–mail or phone.
1–866–584–0355 (toll free) or 903–759–2160 FAX 903–759–4605
color bar gif

If you have comments or suggestions, please email me at James' A/C Co.
Visa, MasterCard, Discover & American Express

   Keyword Search this site--powered by FreeFind

 
 | home |  Educate Me |  Diagnostics |  Refrigeration |  Helpful Hints |  Filters Etc. | 
 | Thermostats |  Condensing Units |  Evaporator Coils |  About Us |  Links |  Store | 
spacer gif Accustat f100 thermostat³
PSG Accustat
®
non-programmable

SALE - $77.22
psg Freedom Advantage thermostat³
Accustat®
Freedom Advantage®

all in one control

honeywell® visionpro™ iaq thermostat³
Honeywell®
VisionPro® IAQ

whole house control

Honeywell® FocusPro™ Thermostat³
Honeywell® FocusPro

non-programmable

Honeywell® VisionPRO™ Thermostat³
Honeywell® VisionPro

Replacement for obsolete Chronotherm III/IV

energy icm Connects Thermostat to Computer and Internet³
in2 Energy ICM®

Connects Thermostat to Computer and Internet.

electronic air cleaner³
Honeywell®
Electronic Air Cleaner

honeywell® media filters³
Honeywell®
Media Filters

UV Lites & Bulb Replacements³
Honeywell®
UV Lights & Bulbs

Honeywell® Carbon Monoxide Alarms³
Honeywell®
Carbon Monoxide
Alarms

Honeywell® Electronic Air Cleaner Replacement Cells³
Honeywell®
Electronic Air Cleaner

Replacement Cells

Honeywell® VisionPro™ Thermostat³
Honeywell®
LineVoltPRO™

programmable

Honeywell's ZD12x8 Zone Damper³
Honeywell
Rectangular Zone Dampers

Honeywell's ARD6 Single Blade Zone Damper³
Honeywell
Round Zone Dampers

Reznor Infrared Suspended Gas Heater³
Reznor
Infrared Heaters