Honeywell® Logo

Honeywell® products
at discounted prices

  HEPA portable filters
HEPA Portable
Powered filter
Chronotherm III Thermostat
Honeywell®
Chronotherm III
Thermostats
Wireless & regular programmable thermostats
Honeywell®
Chronotherm IV
Thermostats
Honeywell® or Skuttle Humidifiers
Honeywell® &
Skuttle® Humidifiers
Reznor Unit Heaters UDAP
Reznor®
Unit Heaters
  
colored bar gif


Educate Me Section

Educate Me/Home
James A/C Co./Home

Diagnosis of problems
Understanding refrigeration
Homeowner helpful hints
Filtration & More
Understanding thermostats
Outside units and safety
Indoor Coils and drains
Links & Search


Air Purification Products

Pleated filters 40% 1 in.
Pleated filters 40% 2 in.
Pleated filters 60% 2 in.
Pleated filters 40% 4 inch
Pleated filters 60% 4 inch
Media filters 4 3/8 inch
Frame & filters 4 3/8 inch
Generic Media
Ultraviolet Lights
Electronic Air Cleaners
EAC Replacement Cells
Prefilters & Postfilters
Airwatch®, Monitors
Ventilation Units
Dampers & Actuators
CO & CO2 Sensors
Smoke Sensors
Portable HEPA Filter
Whole house HEPA Filter
Commercial HEPA Filter


Honeywell® Thermostats

COMPARE --
Programmable.pdf
Non-Programmable.pdf
Non-Digital.pdf

VisionPro™ IAQ *Best
VisionPRO© 8000  *Best
CommercialPRO™8220  *Best
CommercialPRO™7220  *Great
FocusPRO™ 6000  *Great
FocusPRO™ 5000  *Better
PRO™ 4000 *Better
PRO™ 3000 *Good
PRO™ 2000 *Basic
Low Voltage Accustat®
Programmable Line Voltage
Line Voltage Accustat®
Digital Round
Non-Digital bi-metal
Electronic Programmable
Heat Pump
Flush Mount
Non-Programmable
Sale Models
PC8900 Perfect Climate
Outdoor Sensors A or B
Telephone Access
Remote Room Sensors
Communicating Tstat
Telephone Access Module
Wireless Tstat
Internet Conectivity
Networked Zoning
Honeywell® MiniZone®
Flood Alert Switch
Zoning Catalog.pdf
Chronotherm III Owner's Manual



Humidifiers

Bypass Disk
Bypass Flow Through
Power Flow Through
Steam Power
Controls & Components
Skuttle® Parts
Honeywell® Parts


Unit Heaters

Reznor® Garage Heating
Separated Combustion
Used-Oil-Fired
Infrared Heaters
Reznor Parts
Empire® Gas Heaters
What about old heater parts?
What size heater?


HVACR TOOLS

NRP® Manifold Sets
Gauges
Hoses
Heavy Duty Hoses
Miscellaneous


Accessories

Transformers
Contactors
Miscellaneous
Heating Parts
Bell & Gossett Pumps


Email Us
click here and send us an email

James A/C Co.

serving Do-It-Yourselfers since 1990.
Satisfying every customer....one at a time!

Click to verify BBB accreditation and to see a BBB report.

spacer gif
Honeywell Themostats, Filters, and Electronic Air Cleaners
Call toll free 1-866-584-0355 or 1-903-759-2160 fax 903-759-4605
309 Patriot Circle, Longview, TX 75604-2240 colored bar gif

THINGS TO CHECK IF THE HEAD PRESSURE IS TOO LOW:

MOST LIKELY CAUSES:

  • Refrigerant undercharge is probably the most common cause of low head pressure. Refrigerant does not get used up. If the system is checked by subcooling and superheat measurements and indeed found to be low on refrigerant, then there is a LEAK IN THE SYSTEM. Someone has left it with a low charge, or someone or something has let it out. (Don't forget that some people "sniff" anything to get a feeling or bodily reaction. This does occur, too.)

    Household refrigerant is usually refrigerant-22. It is not likely to be dangerous unless inhaled in large quantity. It has the characteristics that allow it to displace oxygen in the air and thus in the body. It is not flammable. In fact, since it displaces oxygen, it retards fire. If breathed in pure state, it will make the voice very low and will give you a faint feeling and later a headache. Enough of it will suffocate you.
    If a refrigerant is in the presence of an open flame or an extremely hot surface, it will turn into a potent acid. The fumes from this acid are very harmful to humans and will cause violent involuntary defensive reactions by a person coming in contact with the vapor.

    Several clues may guide you to finding the leak. Look for oily spots at joints and fittings. About 15% of the systems oil will circulate with the refrigerant. If it leaks, then likely there will be some oil residue at the area of the leak. Check especially the service valves and caps and flare or compression fittings. If you suspect a spot, poor or spray some soapy solution on it to see if it bubbles. Don't necessarily expect large bubbles or a lot of them. Sometimes the leak will only produce a tiny white pin-point size spot. Of course, the technicians will use a very fine and expensive leak detection meter.

    Some leaks are difficult to repair and others are a waste of effort. If the leak is in the body of the evaporator coil, for example, you might as well just buy a new coil and be done with it. If it is in the end-loops of the coils, you may repair it today and the heat around the perimeter of the brazing may later cause several additional leaks to develop. If, however, you are ambitious and willing, then you can braze every joint that is "soldered" and you run a pretty good chance of having a permanent repair. Even this will only give you about a 50% chance, in my opinion, of it being a long lasting and profitable effort. But, if you are good at it and want to try, then go for it.

  • Cool ambient conditions will surely cause the pressures to be low. It is nearly impossible to check the refrigerant system in cool weather. Try to fix it when the outdoor temperature is above 70 degrees F. and the indoor temperature is never below 70 degrees F. If you add refrigerant to a system in too cool conditions, you will invariably overcharge the system.
  • Water on the condenser coils will also result in abnormally low pressures. Let it dry out and avoid even putting your hoses on the equipment in the rain. Even if you don't get moisture in the system, the rain will increase the chances that you might electrocute yourself. Please read the safety precautions from the home page. Always be cautious.
  • LESS LIKELY CAUSES:

  • Inefficient compressor valves, particularly the discharge valves, inside the compressor will produce a reduced head pressure. There is nothing you can do but change the compressor or the condensing unit.
  • TXV stuck open (see explanation in orifice-flow control device in Refrigerants and Charging) will cause an unusually high flow of refrigerant into the low side of the system and will of course reduce the head pressure in the process. Look for excessively high suction pressure and a cooling coil that is not cooling well and a compressor that is being flooded with cold liquid refrigerant. It will be likely be sweating all over and making strange sounds and begging to die. The superheat will be non-existent or excessively low. You may as well replace the TXV (thermostatic Expansion Valve), but you may also take it apart and lightly clean all the moving parts. Don't forget the "push-pins".
  • Iced evaporator will also contribute somewhat to lowering the head pressure. Look for sweating compressor, low or non-existent superheat and lack of adequate airflow from the supply grills from the indoor system. It may, however, seem to have good airflow while not being iced completely. You will likely have to visually examine the evaporator coils.
  • Leaking check-valve (on the heat pumps) will also cause the condition. You can feel the leakage by checking the temperature of the lines as the refrigerant goes through. No repair is likely possible. Change the valve.
    picture of system layout
  • Notice that this drawing of this system has two check valves. One is in the evaporator section and the other is in the condensing unit. The one we are checking now is the one in the evaporator section. Notice the direction-of-flow arrow. In the cooling mode, it is not supposed to let the liquid refrigerant by-pass the expansion valve (TXV) or the capillary tube if you have one or more of them. The check-valve in the condensing unit will be feeding refrigerant through in the correct position during the cooling cycle, so it is supposed to by-pass the flow control device in the condenser during cooling.
spacer gif

honeywell® visionpro™ iaq thermostat
Honeywell®
VisionPro® IAQ

whole house control

Honeywell® FocusPro™ Thermostat
Honeywell® FocusPro

non-programmable

Honeywell® VisionPRO™ Thermostat
in2 Energy ICM®

Connects Thermostat to Computer and Internet.

electronic air cleaner
Honeywell®
Electronic Air Cleaner

honeywell® media filters
Honeywell®
Media Filters

UV Lites & Bulb Replacements
Honeywell®
UV Lights & Bulbs

Honeywell® Carbon Monoxide Alarms
Honeywell®
Carbon Monoxide
Alarms

Honeywell® Electronic Air Cleaner Replacement Cells
Honeywell®
Electronic Air Cleaner

Replacement Cells

Honeywell® VisionPro™ Thermostat
Honeywell®
LineVoltPRO™

programmable

Honeywell's ZD12x8 Zone Damper
Honeywell
Rectangular Zone Dampers

Honeywell's ARD6 Single Blade Zone Damper
Honeywell
Round Zone Dampers

Reznor Infrared Suspended Gas Heater
Reznor
Infrared Heaters

colored bar gif
If you have comments, suggestions or you solved a problem with the aid of this free site,
please email me at James' A/C Co.
Back To Cooling
Back to Front Page

Longnet Web Design
Visa, MasterCard, Discover & American Express