USE THIS LINK FOR A BETTER SCREEN PRESENTATION OF THIS PAGE.

			Reznor® Unit Heater Replacement Parts
		
Reznor has been making heating equipment since 1888.

Many of the heaters from the 1940's and 1950's are still working.
Some replacement parts are available on certain units. 

See Reznor's list of discontinued Model Numbers (manufactured from the 1940s through 2006) 
and replacements where available below:

			
Note: It is imperative that you furnish the unit SERIAL numbers for most Reznor Parts. The following is information that you need to know about the availability of parts for various years and models.
MODEL TYPE LAST MFD. (YEAR) PARTS AVAILABLE CURRENT MODEL
ABB Air Turnover Unit 1999 Limited AEB
ACB Air Turnover Unit 2006 Limited AEB
AEUH Elec. Unit Heater 2000 Limited EGEA
AFA Room Heater 1945 None None
AHCA Split System 2006 Limited PDH, RDH
ARB Air Turnover Unit 1998 Limited AEB
BE Unit Heater 2001 Yes UDBP
CEEXL Unit Heater 1988 Yes UDAP
CEEXLB Unit Heater 1988 Yes UDBP
CPAK Pkgd. Heating/MUA 1997 Yes PGBL, SSCDBL
CREB Pkgd. Heating/MUA 1990 Yes RDH or RPB
CRG Rooftop Duct Furnace 2007 Yes RP
CRGB Rooftop Pkgd. Heating/MUA 2007 Yes RDH or RPB
CRGBL Rooftop Pkgd. Heating/MUA 2007 Yes RPBL
CRP Duct Furnace 1996 Yes RP
CRPAK Pkgd. Heating/MUA 1990 Yes RPBL, RPDBL
CRPBE Pkgd. Heating/MUA 1990 Yes RPB
CRPV Duct Furnace 1996 Yes RPV
CRPVAK Pkgd. Heating/MUA 1990 Yes RPBL, RPDBL
CRPVE Pkgd. Heating/MUA 1990 Yes RPB*, RDH
CRXE Pkgd. Heating/MUA 1990 Yes RPB*, RDH
CX Duct Furnace 1996 Yes X
CXE Pkgd. Heating/MUA 1996 Yes XE
CXL Unit Heater 1988 Yes F
CXLB Unit Heater 1988 Yes B
D Duct Furnace 1956 None X, EEDU
DBF Residential Furnace 1956 None None
DFA Direct Fired Heater 1999 Limited DFC
DFAH Hi-Bay Unit 1975 Limited None
DFB Direct Fired Heater 2006 Limited DFC
DFT Duct Furnace 1977 See Note None
DPAK Pkgd. Heating/MUA 1997 Yes PGBL
DS-LDS Duct Furnace 1964 None X, EEDU
DU Duct Furnace 1952 None X, EEDU
EDF Elec. Duct Furnace 2007 None None
EDFF Elec. Duct Furnace 2004 None None
EDI Elec. Duct Furnace 2007 None None
EDIF Elec. Duct Furnace 2004 None None
EE Elec Furnace 1980 Limited None
EEXL Unit Heater 1988 Yes UDAP
EEXLB Unit Heater 1988 Yes UDBP
ECV Elec. Convection Htr. 2004 None None
EGE Elec. Unit Heater 2004 Limited EGEA
EGH Elec. Unit Heater 2004 Limited EGEA
EJ Elec M.U.A. 1980 Limited None
EPH Elec. Control Panel Htr 2004 None None
EPWP Elec. Pool Water Htr 2004 None None
EPWD Elec. Dishwasher Water Htr. 2004 None None
EPWH Elec. Process Water Htr. 2004 None None
ER Horizontal Hydronic Unit Heater 1993 Limited WS
ERBC Elec Furnace/ Evap CLG 1980 Limited None
ERBJ Elec M.U.A. 1980 Limited None
ERC Elec W/Evap CLG 1980 Limited None
ERC Elec. Radiant Htr. 2004 None ERSF/ERSP
ERE Elec Furnace 1980 Limited None
ERE Elec. Radiant Htr. 2004 None ERSF/ERSP
ERHC Elec. Radiant Htr. 2004 None ERSF/ERSP
ERHQT Elec. Radiant Htr. 2004 None ERSF/ERSP
ERHR Elec. Radiant Htr. 2004 None ERSF/ERSP
ERIC Elec. Radiant Htr. 2004 None ERSF/ERSP
ERIH Elec. Radiant Htr. 2004 None ERSF/ERSP
ERIE Elec. Radiant Htr. 2004 None ERSF/ERSP
ERIQF Elec. Radiant Htr. 2004 None ERSF/ERSP
ERIQL Elec. Radiant Htr. 2004 None ERSF/ERSP
ERIQT Elec. Radiant Htr. 2004 None ERSF/ERSP
ERIR Elec. Radiant Htr. 2004 None ERSF/ERSP
ERJ Elec M.U.A. 1980 Limited None
ERQL Elec. Radiant Htr. 2004 None ERSF/ERSP
ERQT Elec. Radiant Htr. 2004 None ERSF/ERSP
ERSA Energy Recovery 2003 Yes XAWS, XAWU, XBWS, XBWU
EUH Elec. Unit Heater 2000 Limited EGEA
EVSB Electric Boiler 2004 None None
EVWB Electric Boiler 2004 None None
EXCA Elec. Convection Htr. 2004 None None
EXCB Elec. Convection Htr. 2004 None None
EXU Elec. Explosion Resis. Htr 2004 None EXUA
FE Unit Heater 2001 Yes UDAP
FM Room Heater 1962 None None
FT Unit Heater 2001 Yes UDAP
HC Hydronic Cabinet Heater 1999 Yes None
HCREB Pkgd. Heating/MUA 1990 Yes RDH, RPB
HCRG Rooftop Duct Furnace 2006 Yes RP
HCRGB Rooftop Pkgd. Heating/MUA 2006 Yes RDH, RPB
HCRGBL Rooftop Pkgd. Heating/MUA 2006 Yes RPBL
HCRP Duct Furnace 1996 Yes HRP
HCRPBE Pkgd. Heating/MUA 1990 Yes RDH, HRPB
HCRPV Duct Furnace 1996 Yes HRPV
HCRPVE Pkgd. Heating/MUA 1990 Yes RDH, HRPB*
HCRXE Pkgd. Heating/MUA 1990 Yes RDH, HRPB*
HCX Duct Furnace 1996 Yes HX
HCXE Pkgd. Heating/MUA 1996 Yes HXE
HH Hydronic Unit Heater 1999 Yes WS
HR Heat Recovery 1981 Yes None
HRA Heat Recovery 1981 Yes None
HRB Heat Recovery 1981 Yes None
HREB Pkgd. Heating/MUA 1990 Yes RDH, HRPB
HRG Rooftop Duct Furnace 2006 Yes RP
HRGB Rooftop Pkgd. Heating/MUA 2006 Yes RDH, RPB
HRGBL Rooftop Pkgd. Heating/MUA 2006 Yes RPBL
HRPBE Pkgd. Heating/MUA 1990 Yes RDH, HRPB
HRPVE Pkgd. Heating/MUA 1990 Yes RDH, HRPB*
HRXE Pkgd. Heating/MUA 1990 Yes RDH, HRPB*
HV Hydronic Unit Heater 1999 Yes WS
IR Infared 1964 None RIHN,RIHL,RIHVN,RIHVL
IR-IP Infared 1959 None RIHN,RIHL,RIHVN,RIHVL
LUSB Unit Heater 1964 Limited UDBP
LUSF Unit Heater 1964 Limited UDAP
OB Oil Fired (Blower Type) Htr. 2006 Limited None
OUB250-300 Oil Fired 1988 Limited None
OUB95, 140, 185 Oil Fired 1992 Limited None
OUD Oil Duct Furnace 1978 Limited None
OUE Oil, F.A.F 1978 Limited None
OUH250-300 Oil Fired 1988 Limited None
OUH95, 140, 185 Oil Fired 1992 Limited OH
PAA Pkgd. Heating/MUA 1999 Limited CAUA, PCDH, PCDV
PAB Pkgd. Heating/MUA 1998 Limited PCDH, PCDV
PAC Pkgd. Heating/MUA 1998 Limited PCDH, PCDV
PAK Pkgd. Heating/MUA 1997 Yes PGBL, SSCDBL
PBB Pkgd. Heating/MUA 1998 Limited PCDH, PCDV
PBC Pkgd. Heating/MUA 1999 Limited PCDH, PCDV
PCBH Pkgd. Heating/MUA 2006 Limited PCDH
PCBV Pkgd. Heating/MUA 2006 Limited PCDV
PCCA Pkgd. Cooling & Heating 2003 Limited RCA, RDCA, RECA
PCCH Pkgd. Cooling & Heating 2000 Limited RCA, RDCA, RECA
PCCR Pkgd. Cooling & Heating 2000 Limited RCA, RDCA, RECA
PCDA Pkgd. Cooling & Heating 2003 Limited RDA, RDDA, REDA
PV Sep Comb Duct Furnace 1973 Yes SC
PVA Sep Comb Unit Heater 1973 Yes UDAS
PVB Sep Comb Unit Heater 1973 Yes UDBS
PVC Sep Comb Unit Heater 1973 Yes SDH
PVD Sep Comb Hi-Bay Unit 1973 Yes None
PVE Sep Comb F.A.F. 1973 Yes SDH
RAM Evaporative Cooling 1990 Limited REC
XL Unit Heater ???? Limited-no heat exchangers or burner racks UDAP, UDAS, UEAS.
XLB Unit Heater W/Blower ???? Limited UDAP, UDAS, UEAS.

			Other units not listed above.

Model Reznor file nomenclature
                        (www.RezSpec.com)

RBB ....... P-X/XE/RX/RPV
RBA ........... P-RG/RP/RBL
RBHB .... P-X/XE/RX/RPV
RBHA ........ P-RG/RP/RBL
RBL ............ P-RG/RP/RBL
RCA .................... P-MAPS
RDA .................... P-MAPS
RDCA ................. P-MAPS
RDDA ................. P-MAPS
RECA .................. P-MAPS
REDA ................. P-MAPS
RDF ......................... P-RDF
REBB .... P-X/XE/RX/RPV
REBJB ... P-X/XE/RX/RPV
REC ......................... P-REC
RG .............. P-RG/RP/RBL
RGB ........... P-RG/RP/RBL
RGBL ......... P-RG/RP/RBL
RIH........... P-VR/TRP/RIH
RIHV........ P-VR/TRP/RIH
RP ............... P-RG/RP/RBL
RPAKB ................... P-PAKC
RPB ............ P-RG/RP/RBL
RPBEB .. P-X/XE/RX/RPV
RPBL.......... P-RG/RP/RBL
RPDBL....... P-RG/RP/RBL
RPV ...... P-X/XE/RX/RPV
RPVAKB ................ P-PAKC
RPVEB .. P-X/XE/RX/RPV
RTNB ............. P-RTN/RTLC
RTLB .............. P-RTN/RTLC
RX ........ P-X/XE/RX/RPV
RXEB .... P-X/XE/RX/RPV
RXJB ..... P-X/XE/RX/RPV
SC ............................... P-SC
SCAB .......................... P-SC
SCBB ........................... P-SC
SCE ............................ P-SC
SFTB ...................P-FT/SFT
SHE ..........................I-SHE
SSCBL ....................... P-SC
SSCDBL .................... P-SC
TR ............................ P-TRC
TRP .......... P-VR/TRP/RIH
UAB ...... P-X/XE/RX/RPV
UDAP ....................... P-UD
UDAS ....................... P-UD
UDBP ........................P-UD
UDBS ........................P-UD
VR ............ P-VR/TRP/RIH
WS..................................... C
X ........... P-X/XE/RX/RPV
XAB ...... P-X/XE/RX/RPV
XBB ....... P-X/XE/RX/RPV
XCB ....... P-X/XE/RX/RPV
XE ........ P-X/XE/RX/RPV
XJB ........ P-X/XE/RX/RPV
XLB ............................ P-XL
XLBB ......................... P-XL
All Other Units .................

Above information is provided by Reznor

What size heater do I need for a space/room that measures
(x ft. wide by y ft. deep)

Although this may seem like a simple question that can have a simple answer, 
it really isn't. In order to determine the size heater that is needed for a 
specific application, many factors have to be considered including:

	What is the cubic feet of the room? (length x width x height)

	What is the insulation value of the walls, ceiling, floor, and any windows?

	Are any adjacent room (beside, above or below) heated?

	Where are you located? (a larger heater is needed in New York than New Orleans)

	How much infiltration is there? (Cold air entering the room through cracks around 
	   window sills, or loading dock doors that periodically open and close)

	What is the normal outside temperature during the heating season?

	Where do you want to maintain the inside temperature?

	Is there any inside air being exhausted to the outside? (manufacturing processes, 
	   kitchen exhaust hoods, restrooms, laboratory exhaust hoods, etc.)

	Will you simply be recirculating the heated inside air, or do you 
	   want to introduce fresh air from outside into the heated space?

Other areas would need to be explored including the local building codes. For an 
accurate heating needs analysis, contact your local representative at 800-695-1901. 
In most cases an estimate can be given over the phone. For an exact analysis an on-site 
inspection by a qualified HVAC engineer may be required.